Use shock-absorbing mounts rated for the device weight plus 20 percent margin. Rubber isolators reduce vibration transfer. Avoid over-tightening which can warp the chassis and affect touch alignment.
Power Conditioning
Vehicle systems fluctuate between 9 and 36 volts DC. Use a DC-DC converter with clean regulated output and transient suppression. Include a fuse and reverse polarity protection.
Cable Routing
Secure cables along support arms with clips every six inches. Use locking HDMI or USB connectors. Leave a short service loop to prevent tension during movement.
Wireless Connectivity
Vehicle Wi Fi signals can fade in metal interiors. Use external antennas with magnetic mounts for better range.
Environmental Factors
Temperature swings cause condensation. Place displays away from direct cold-air vents. If required, use enclosures with mild heating elements.
Example
A warehouse fleet fitted ELO touch displays to forklifts for digital pick lists. After installing damped mounts and converters, touch reliability stayed at 100 percent across two winters.
Final Thoughts
ELO hardware adapts to moving environments when mechanical, electrical, and thermal conditions are planned carefully. Mobility requires engineering, not compromise.